  • Caustic corrosion in a boiler waterside tube: Root cause

    Mar 01, 2013 · There are two main factors in occurrence of caustic corrosion: (1) presence of caustics in boiler water and (2) concentration mechanism. With respect to the water treatment program applied, caustic soda was added to the water. Moreover, after restarting the …Learn More

  • Guides and Recommended Procedures For Water Treatment

    2. the boiler-water must contain caustic, 3. at least a trace of silica must be present in the boiler-water, and. 4. some mechanisms, such as a slight leak, must be present to allow the boiler water to concentrate on the stressed metal. Stem blanketing is a condition that occurs when a steam layer forms between the boiler water and the tube wall.Learn More

  • The International Association for the Properties of Water

    Makeup Water MU Water which is added to compensate for losses of water and steam from the system Mono-sodium phosphate MSP NaH2PO4 Once-through boiler or HRSG Benson Boiler Boiler in which output steam is generated from input water by complete evaporation. There is no recirculation of boiler water. Oxygenated Treatment OT Combined WaterLearn More

  • Prevention and Treatment for Scale Control

    Caustic soda is used when the feedwater cannot build up the required causticity residual in the boiler water. Use of soda ash (Na 2 CO 3) is not authorized in steaming boilers because it breaks down under heat to form undesired carbon dioxide (CO 2). This gas is corrosive to condensate return lines.Learn More

  • pH Treatment | CleanBoiler.org

    Caustic soda (NaOH) is the only normal boiler water constituent that has high solubility and does not crystallize under typical boiler conditions. Its caustic concentration can be as high as 10,000-100,000 ppm. Careful control of boiler water chemistry can prevent caustic gouging. If the "free hydroxide alkalinity" is set too high or uncontrolled, then caustic gouging may result. Prevention of porous …Learn More

  • EC: Lesson 11. Scale and sludge formation in boilers

    Caustic embrittlement is a type of boiler corrosion, caused by using highly alkaline water in the boiler. During softening process by lime-soda process, free Na 2 CO 3 is usually present in small proportion in the softened water.Learn More

  • Caustic corrosion in a boiler waterside tube: Root cause

    Aug 26, 2019 · August 26, 2019. Caustic soda (sodium hydroxide, or NaOH) is a commonly used water treatment chemical that raises the pH of water by absorbing water and carbon dioxide. Bell Chem, your water treatment chemical supplier, keeps abundant supplies of caustic soda on hand for your treatment needs. Read below to learn how sodium hydroxide can benefit Learn More

  • Test for Caustic Alkalinity (OH) with Tannin

    When causticity is too high, blow down; if too low, add sodium hydroxide (caustic soda). Test for Caustic Alkalinity (OH) with Tannin . For this test, start with a warm sample of about 160F. It may be reheated by placing the sample-collecting container in a stream of hot boiler water drawn through the boiler water cooler connection.Learn More

  • Caustic corrosion in boilers - Lenntech

    What is Caustic Corrosion? - Definition from CorrosionpediaLearn More

  • Water Handbook - Preboiler & Industrial Boiler Corrosion

    In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used. In the boiler, either high or low pH increases the corrosion rates of mild steel (see Figure 11-10).Learn More

  • BOILER WATER TREATMENT AND CONDENSATE RETURN …

    If soda ash is used for boiler water treatment it too breaks down in the boiler to form caustic soda and carbon dioxide. This simply increases the corrosion problem, and, if you are using a neutralizing amine it increases your cost. Inasmuch as caustic soda is already reverted to the final pro-duct, no carbon dioxide is given off in the boiler.Learn More

  • Boiler Feedwater Treatment (Part II): Water Treatment

    Sodium nitrate inhibits embrittlement at low concentrations ranging to 0.4 part of sodium nitrate per part of caustic soda in boiler water. Maintaining an organic content of 50-100 ppm and a sodium nitrate content of 50 ppm is a commonly used embrittlement prevention program.Learn More

  • WATER TECHNOLOGY - khitguntur.ac.in

    a. It is a type of boiler corrosion caused by using highly alkaline water in the boiler. b. During softening process by Lime-Soda process, free N a2 CO 3 is usually present in small proportion. c. In high pressure boilers, Na 2 CO3 decomposes to give NaOH and CO 2 and this makes the boiler water 'caustic'. Na 2 CO 3 + H2O → 2NaOH + CO 2 d.Learn More

  • Mining and Refining – Process - World Aluminium

    The spent liquor is heated through a series of heat exchangers and subsequently cooled in a series of flash tanks. The condensate formed in the heaters is re-used in the process, for instance as boiler feed water or for washing bauxite residue. The remaining caustic soda is washed and recycled back into the digestion process. 7. ClassificationLearn More

  • Different Types of Corrosion: Caustic Embrittlement

    Caustic soda (NaOH) was added in small amounts to boiler water to prevent scaling but the presence of caustics (alkalis), usually concentrated in crevices around rivet heads and at hot spots, combined with the considerable fabrication stresses around rivet holes to caused cracking of …Learn More

  • Boiler Lay-Up Procedure to Minimize Damage

    First, perform the dry lay-up steps 1-6. 7 — Filling the Boiler with Water and Treatment Chemicals. The alkalinity should be adjusted to greater than 400 ppm for this boiler maintenance step. This prevents acidic corrosion of the waterside. Tri-sodium phosphate or caustic soda has been used in the past to accomplish this (about 3 pounds/1000 Learn More

  • Rusty boiler innards and water treatment | Smokstak

    Jan 14, 2021 · The scale sized boiler product is LSB 8000. They have the same working ingredients, the difference is concentration and package size. The industrial twin to LSB 4000 is called BWT, for Boiler Water Treatment. There is a 3X strength cleaning formula called …Learn More

  • Rusty boiler innards and water treatment | Smokstak

    Jan 14, 2021 · The scale sized boiler product is LSB 8000. They have the same working ingredients, the difference is concentration and package size. The industrial twin to LSB 4000 is called BWT, for Boiler Water Treatment. There is a 3X strength cleaning formula called …Learn More

  • Boiler Boil-Out Suggestions - Banks Engineering

    Boil-out chemicals are highly caustic. Caustic Soda Ash will produce a violent flash if introduced to water too rapidly. Employees handling the chemicals must wear protective equipment, I.E. Goggles, gloves, aprons, etc.. and an emergency shower should be nearby. Use vinegar as an antidote. Check for proper voltages, fuses, and overloads.Learn More

  • Lay-up of Heating Boilers - National Board of Boiler and

    If hot water is not available, heat the water using the boiler's burner after the water level reaches the lowest permissible level as marked on the boiler. Vent the air and gases as needed. Since there is no feed or condensate tank to introduce the treatment chemicals on water boilers, it is recommended the chemicals be premixed with water Learn More

  • boiler water softening/ treatment, etc | Hearth.com Forums

    Oct 25, 2011 · for background, my domestic water, which comes from a great 180 year old spring, is both hard and acidic at the same time. comes up as about pH 5.2 on test strips has lots of some kind of hard minerals in it; laundry works OK, faucets and fixtures do not clog, but pots and pans scale up fastLearn More

  • Boiler Lay-Up Procedure to Minimize Damage

    First, perform the dry lay-up steps 1-6. 7 — Filling the Boiler with Water and Treatment Chemicals. The alkalinity should be adjusted to greater than 400 ppm for this boiler maintenance step. This prevents acidic corrosion of the waterside. Tri-sodium phosphate or caustic soda has been used in the past to accomplish this (about 3 pounds/1000 Learn More

  • Lay-up of Heating Boilers - National Board of Boiler and

    If hot water is not available, heat the water using the boiler's burner after the water level reaches the lowest permissible level as marked on the boiler. Vent the air and gases as needed. Since there is no feed or condensate tank to introduce the treatment chemicals on water boilers, it is recommended the chemicals be premixed with water Learn More

  • Caustic corrosion in a boiler waterside tube: Root cause

    Mar 01, 2013 · There are two main factors in occurrence of caustic corrosion: (1) presence of caustics in boiler water and (2) concentration mechanism. With respect to the water treatment program applied, caustic soda was added to the water. Moreover, after restarting the …Learn More

  • Boiler Treatment, Lecture 3 | Ion Exchange | Zeolite

    Boiler feed water should satisfy hardness(0.2 ppm), caustic alkalinity(0.15-0.45 ppm), soda alkalinity(0.15-1.0 ppm) and soda ash(0.30.55 ppm). In order to satisfy these specifications boiler feed water is treated in 2 stages : (i) External treatment (ii) Internal treatmentLearn More